Behavioral Studies of Myoware Sensor During Automated Prosthetic Implementation
DOI:
https://doi.org/10.37591/rrjols.v10i1.2563Abstract
Abstract The revolutionary evolution in the field of biosensors have led to many innovations in the field of biomedical implants, prosthetics or orthotics, robotics, wearable medical devices, health monitoring systems and fitness bands. This study is about myoware sensors that works on principle of electromyography captured by myoware sensors based on electric potentials. A raw EMG signal is synthesized by amplification, rectification and integration of signals that is ready to use and programmed by any micro-controllers or ADCs’ that were observed during the implementation of an automated prosthetics system for a human cru. Locomotion of a static pylon is attained by placing the myoware sensors at different muscles. The following two case studies are considered such as: [a] placing the myoware sensor on Rectus Femoris and operate the prosthetic limb when there is a valid signal computed by the micro-controller with the sensor’s reading, [b] placing the myoware sensor on Deltoids and operate the prosthetic limb when there is a valid signal computed by the micro-controller with the sensor’s readings.
Keywords: Myoware, Sensors, Micro-Controllers, Prosthetics, Medical Devices
Cite this Article Madhu Mohan R., Girisha C., Vijayalakshmi K., Karthik C., Harish G., Piyush M. Behavioral Studies of Myoware Sensor During Automated Prosthetic Implementation. Research & Reviews: A Journal of Life Sciences. 2020; 10(1): 10–15p.
Downloads
Published
Issue
Section
License
Declaration and Copyright Transfer Form
(to be completed by authors)
I/ We, the undersigned author(s) of the submitted manuscript, hereby declare, that the above manuscript which is submitted for publication in the STM Journals(s), is not published already in part or whole (except in the form of abstract) in any journal or magazine for private or public circulation, and, is not under consideration of publication elsewhere.
- I/We will not withdraw the manuscript after 1 week of submission as I have read the Author Guidelines and will adhere to the guidelines.
- I/We Author(s ) have niether given nor will give this manuscript elsewhere for publishing after submitting in STM Journal(s).
- I/ We have read the original version of the manuscript and am/ are responsible for the thought contents embodied in it. The work dealt in the manuscript is my/ our own, and my/ our individual contribution to this work is significant enough to qualify for authorship.
- I/We also agree to the authorship of the article in the following order:
Author’s name
1. ________________
2. ________________
3. ________________
4. ________________
| We Author(s) tick this box and would request you to consider it as our signature as we agree to the terms of this Copyright Notice, which will apply to this submission if and when it is published by this journal. |